| Basic function | easyE4 basic device |
| Description | Electronic control relaywith displaywith Ethernet interfaceExpandable with the easyE4 series of digital input/output expansions with easy-E4-CONNECT1 connector (Item Y7-197225)Rated operating voltage 12V DC, 24V DC or 24V AC8 digital inputs, No. of these can be used as analog inputs - 4Digital outputs: 4 relaysScrew terminalsDelivery with customized user program is possible via Item (Y7) -2010781 EASY-COMBINATION |
| Inputs | |
| Digital | 8 |
| of which can be used as analog | 4 |
| Outputs | |
| Quantity of outputs | Relay: 4 |
| Additional features | |
| Real time clock | ✔ |
| Display & keypad | ✔ |
| Expansions | Expandablenetworkable (Ethernet) |
| Supply voltage | 12/24 V DC24 V AC |
| Software | EASYSOFT-SWLIC/easySoft 7 |
| General | |
| Standards | EN 61000-6-2EN 61000-6-3IEC 60068-2-6IEC 60068-2-27IEC 60068-2-30IEC 61131-2EN 61010EN 50178 |
| ApprovalsApprovals | cULus |
| Approvalscertificate | CE |
| Approvalsshipping classification | DNV GL |
| Approvals | |
| Dimensions (W x H x D) | 71.5 x 90 x 58 mm |
| Weight | 0.215 kg |
| Mounting | Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories) |
| Connection type | screw terminal |
| EthernetConnections | RJ45 plug, 8-pin |
| EthernetCable | CAT5 |
| Terminal capacities | |
| Screw terminalsSolid | 0.2 - 4 mm2 |
| Screw terminalsflexible | 0.2 - 2.5 mm2 |
| Screw terminalsSolid or flexible conductor, with ferrule | 0,2 - 2,5 mm2 |
| Screw terminalsSolid or stranded | 22 - 12 AWG |
| Screw terminalsStandard screwdriver | 0.8 x 3.5 mm |
| Screw terminalsTightening torque | 0.5 - 0.7 Nm |
| Screw terminalsStripping length | 6.5 мм |
| Display | |
| Display - Type | Monochrome |
| Lines x characters | 6 x 16 |
| Climatic environmental conditions | |
| Operating ambient temperature | -25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C |
| Condensation | Take appropriate measures to prevent condensation |
| LCD display (clearly legible) | 0 - 55 °C |
| Storage [ϑ] | -40 - +70 °C |
| relative humidity | in accordance with IEC 60068-2-30, IEC 60068-2-785 - 95 % |
| Air pressure (operation) | 795 - 1080 hPa |
| Ambient conditions, mechanical | |
| Protection type (IEC/EN 60529, EN50178, VBG 4) | IP20 |
| Vibrations | In accordance with IEC 60068-2-6constant amplitude 0.15 mm: 10 - 57constant acceleration 2 g: 57 - 150 Hz |
| Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms | 18 Impacts |
| Drop to IEC/EN 60068-2-31 [Drop height] | 50 мм |
| Free fall, packaged (IEC/EN 60068-2-32) | 0.3 m |
| Mounting position | Vertical or horizontal |
| Electromagnetic compatibility (EMC) | |
| Overvoltage category/pollution degree | III/2 |
| Electrostatic discharge (ESD)applied standard | according to IEC EN 61000-4-2 |
| Electrostatic discharge (ESD)Air discharge | 8 kV |
| Electrostatic discharge (ESD)Contact discharge | 6 kV |
| Electromagnetic fields (RFI) to IEC EN 61000-4-3 | 0.8 - 1.0 GHz: 101.4 - 2 GHz: 32.0 - 2.7 GHz: 1 V/m |
| Radio interference suppression | EN 61000-6-3 Class B |
| Burst | according to IEC/EN 61000-4-4Supply cables: 2Signal cables: 2 kV |
| power pulses (Surge) | according to IEC/EN 61000-4-51 kV (supply cables, symmetrical)2 kV (supply cables, asymmetrical) |
| Immunity to line-conducted interference to (IEC/EN 61000-4-6) | 10 V |
| Insulation resistance | |
| Clearance in air and creepage distances | nach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
| Insulation resistance | per EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
| Back-up of real-time clock | |
| Back-up of real-time clock | |
| ① Backup time (hours) with fully charged double layer capacitor② Service life (years) | |
| Accuracy of real-time clock to inputs | typ. ± 2 (± 0.2 h⁄Year) s/day |
| depending on ambient air temperature fluctuations of up to ± 5 s/day (± 0.5 h⁄year) are possible | |
| Repetition accuracy of timing relays | |
| Accuracy of timing relays (of values) | ± 0.02 % |
| ResolutionRange “S” | 5 ms |
| ResolutionRange “M:S” | 1 s |
| ResolutionRange “H:M” | 1 min |
| Power supply | |
| Rated operational voltage [Ue] | 12/24 DC (-15/+20%)24 AC (-15/+10%) V |
| Permissible range [Ue] | 10.2 - 28.8 V DC20.4 - 26.4 V AC |
| Residual ripple | ≦ 5 % |
| Siemens MPI, (optional) | yes |
| Frequency | 50/60 (± 5%) Hz |
| Input current | max. 200 mA at 12 V DCmax. 125 mA at 24 V DC |
| Voltage dips | ≤ 20 ms at 24 V AC10 ms at 24 V DC1 ms at 12 V DC ms |
| Fuse | ≧ 1A (T) A |
| Power loss [P] | Normally 3 W |
| Heat dissipation at 24 V DC | 3 W |
| Digital inputs 12 V DC | |
| Number | 8 |
| Status Display | LCD-Display |
| Potential isolation | from power supply: noto the memory card: noto Ethernet: yesbetween inputs: nofrom the outputs: yesto expansion devices: yes |
| Rated operational voltage [Ue] | 12 V DC |
| Input voltage | Condition 0: ≦ 5 (I1 - I8)Condition 1: ≧ 8 (I1 - I8) V DC |
| Input current at signal 1 | 1.75 mA (I1 - I4)0.9 mA (I5 - I8) mA |
| Deceleration time | 20 (0 -> 1/1 -> 0, Debounce ON)type 0.015 (0 -> 1/1 -> 0, Debounce OFF) ms |
| Cable length | 100 (unshielded) m |
| Frequency counterNote | Notes on this, see under Digital inputs 24 V DC |
| Incremental counterNote | Notes on this, see under Digital inputs 24 V DC |
| Rapid counter inputsNote | Notes on this, see under Digital inputs 24 V DC |
| Digital inputs 24 V DC | |
| Number | 8 |
| Inputs can be used as analog inputs | 4 (I5, I6, I7, I8) |
| Status Display | LCD-Display |
| Potential isolation | from power supply: noto the memory card: noto Ethernet: yesbetween inputs: nofrom the outputs: yesto expansion devices: yes |
| Rated operational voltage [Ue] | 24 V DC |
| Input voltage | Signal 0: ≦ 5 (I1 - I8)Condition 1: ≧ 15 (I1 - I8) V DC |
| Input current at signal 1 | 3.3 (I1 – I4)1.8 (I5 – I8) mA |
| Deceleration time | 20 (0 -> 1/1 -> 0, Debounce ON)type 0.015 (0 -> 1/1 -> 0, Debounce OFF) ms |
| Cable length | 100 (unshielded) m |
| Frequency counterNumber | 4 (I1, I2, I3, I4) |
| Frequency counterCounter frequency | ≦ 10 kHz |
| Frequency counterPulse shape | Square |
| Frequency counterPulse pause ratio | 1:1 |
| Frequency counterCable length | ≦ 20 (screened) m |
| Incremental counterNumber of counter inputs | 2 (I1 + I2, I3 + I4) |
| Incremental counterValue range | -2147483648 to +2147483647 |
| Incremental counterCounter frequency | ≦ 10 kHz |
| Incremental counterPulse shape | Square |
| Incremental counterSignal offset | 90° |
| Incremental counterPulse pause ratio | 1:1 |
| Incremental counterCable length | ≦ 20 (screened) m |
| Rapid counter inputsNumber | 4 (I1, I2, I3, I4) |
| Rapid counter inputsValue range | -2147483648 to +2147483647 |
| Rapid counter inputsCounter frequency | ≦ 10 kHz |
| Rapid counter inputsPulse shape | Square |
| Rapid counter inputsPulse pause ratio | 1:1 |
| Rapid counter inputsCable length | ≦ 20 (screened) m |
| Digital inputs 24 V AC | |
| Number | 8 |
| Status Display | LCD-Display |
| Potential isolation | from power supply: noto the memory card: noto Ethernet: yesbetween inputs: nofrom the outputs: yesto expansion devices: yes |
| Rated operational voltage [Ue] | 24 V AC |
| Input voltage (AC = sinusoidal) [Ue] | Status 0: ≦ 5 (I1 - I8)Condition 1: ≧ 14 (I1 - I8) V |
| Rated frequency | 50/60 Hz |
| Input current at signal 1 | I1 - I4: 3.5 (at 24 VAC/DC)I5 - I8: 1.8 (at 24 VAC/DC) mA |
| Deceleration time | 45/38 (0 -> 1/1 -> 0, debounce ON 50/60Hz)type 25⁄21 (0 - > 1/1 -> 0, debounce OFF 50/60Hz) ms |
| Cable length | 40 (unshielded) m |
| Analog inputs | |
| Number | 4 (I5, I6, I7, I8) |
| Potential isolation | from power supply: noto the memory card: noto Ethernet: yesbetween inputs: nofrom the outputs: yesto expansion devices: yes |
| Input type | DC voltage |
| Signal range | 0-10 V DC |
| Resolution | 12 Bit (value 0 - 4095) |
| Input impedance | 13.3 kΩ |
| Accuracy of actual valuetwo devices from series | ± 3 , ± 0.12 V % |
| Accuracy of actual valueWithin a single device | ± 2, ± 0.12 V % |
| Conversion time, analog/digital | each CPU cycle ms |
| Input current | < 1 mA |
| Cable length | ≦ 30, screened m |
| Relay outputs | |
| Number | 4 |
| Outputs in groups of | 1 |
| Parallel switching of outputs for increased output | Not allowed |
| Protection of an output relay | Miniature circuit-breaker B16 or slow-blow 8 A fuse |
| Potential isolation | Safe isolation according to EN 50178: 300 V ACBasic isolation: 600 V ACfrom power supply: yesFrom the inputs: yesbetween outputs: yesto Ethernet: yesto expansion devices: yes |
| ContactsConventional thermal current (10 A UL) | 8 A |
| ContactsRecommended for load: 12 V AC/DC | > 500 mA |
| ContactsRated impulse withstand voltage Uimp of contact coil | 6 kV |
| ContactsRated operational voltage [Ue] | 240 V AC |
| Rated insulation voltage [Ui] | 240 V AC |
| Safe isolation according to EN 50178 | 300 between coil and contact300 between two contacts V AC |
| Making capacityAC–-15, 250 V AC, 3 A (600 ops./h) [Operations] | 300000 |
| Making capacityDC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations] | 200000 |
| Breaking capacity AC-15, 250 V AC, 3 A (600 Ops./h) [Operations] | 300000 |
| Breaking capacity DC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations] | 200000 |
| Filament bulb load1000 W at 230/240 V AC [Operations] | 25000 |
| Filament bulb load500 W at 115/120 V AC [Operations] | 25000 |
| Fluorescent lamp loadFluorescent lamp load 10 x 58 W at 230/240 V ACWith upstream electrical device [Operations] | 25000 |
| Fluorescent lamp loadFluorescent lamp load 10 x 58 W at 230/240 V ACUncompensated [Operations] | 25000 |
| Fluorescent lamp loadFluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated [Operations] | 25000 |
| Switching frequencyMechanical operations | 10 x 106 |
| Switching frequencySwitching frequency | 10 Hz |
| Switching frequencyResistive load/lamp load | 2 Hz |
| Switching frequencyInductive load | 0.5 Hz |
| UL/CSAUninterrupted current at 240 V AC | 10 A |
| UL/CSAUninterrupted current at 24 V DC | 8 A |
| UL/CSAACControl Circuit Rating Codes (utilization category) | B 300 Light Pilot Duty |
| UL/CSAACMax. rated operational voltage | 300 V AC |
| UL/CSAACmax. thermal continuous current cos ϕ = 1 at B 300 | 5 A |
| UL/CSAACmax. make/break cos ϕ ≠ capacity 1 at B 300 | 3600/360 VA |
| UL/CSADCControl Circuit Rating Codes (utilization category) | R 300 Light Pilot Duty |
| UL/CSADCMax. rated operational voltage | 300 V DC |
| UL/CSADCMax. thermal uninterrupted current at R 300 | 1 A |
| UL/CSADCMax. make/break capacity at R 300 | 28/28 VA |
| Supply voltage UAux | |
| Power loss [P] | 3 W |
| Ethernet | |
| Data transfer rate | 10/100 Mbit/s |
| Connections | RJ45 plug, 8-pin |
| Cable | CAT5 |
| Technical data for design verification | |
| Static heat dissipation, non-current-dependent [Pvs] | 3 W |
| Operating ambient temperature min. | -25 °C |
| Operating ambient temperature max. | +55 °C |
| IEC/EN 61439 design verification | |
| 10.2 Strength of materials and parts10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2 Strength of materials and parts10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2 Strength of materials and parts10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of ASSEMBLIES | Meets the product standard's requirements. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9 Insulation properties10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9 Insulation properties10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| PLC's (EG000024) / Logic module (EC001417) | |
| Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / Logic module (ecl@ss10.0.1-27-24-22-16 [AKE539014]) | |
| Supply voltage AC 50 Hz | 20.4 - 28.8 V |
| Supply voltage AC 60 Hz | 20.4 - 28.8 V |
| Supply voltage DC | 10.2 - 28.8 V |
| Voltage type of supply voltage | AC/DC |
| Switching current | 8 A |
| Number of analogue inputs | 4 |
| Number of analogue outputs | |
| Number of digital inputs | 8 |
| Number of digital outputs | 4 |
| With relay output | Yes |
| Number of HW-interfaces industrial Ethernet | 1 |
| Number of interfaces PROFINET | |
| Number of HW-interfaces RS-232 | |
| Number of HW-interfaces RS-422 | |
| Number of HW-interfaces RS-485 | |
| Number of HW-interfaces serial TTY | |
| Number of HW-interfaces USB | |
| Number of HW-interfaces parallel | |
| Number of HW-interfaces Wireless | |
| Number of HW-interfaces other | 1 |
| With optical interface | No |
| Supporting protocol for TCP/IP | Yes |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for MODBUS | Yes |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Radio standard UMTS | No |
| IO link master | No |
| Redundancy | No |
| With display | Yes |
| Degree of protection (IP) | IP20 |
| Basic device | Yes |
| Expandable | Yes |
| Expansion device | No |
| With timer | Yes |
| Rail mounting possible | Yes |
| Wall mounting/direct mounting | Yes |
| Front build in possible | Yes |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| Category according to EN 954-1 | None |
| SIL according to IEC 61508 | None |
| Performance level acc. EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Appendant operation agent (Ex ib) | No |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |
| Width | 71.5 мм |
| Height | 90 мм |
| Depth | 58 мм |
| UL File No. | E205091 |
| UL Category Control No. | NRAQ/7 |
| North America Certification | UL listed |
| Degree of Protection | IEC: IP20, UL/CSA Type: - |
На этой странице вы можете приобрести Eaton Программируемое реле 24V DC, цифровые 8 DI (4 могут использоваться как как аналог.), 4DO транз., дисплей+клавиатура, часы реального времени, Ethernet RJ45 (артикул: 0000197211). Мы рекомендуем внимательно изучить представленные технические характеристики и ознакомиться с официальными брошюрами от Eaton, чтобы выбрать товар в нужной конфигурации.
Для покупки модели EASY-E4-UC-12RC1 просто нажмите кнопку «В корзину» и перейдите в корзину для оформления заказа. Большинство наших товаров имеются в наличии на складе; в случае отсутствия необходимой позиции мы обеспечим её поставку под заказ.
После оформления заказа наши менеджеры оперативно свяжутся с вами для уточнения деталей оплаты и наиболее удобных вариантов доставки.
Преимущества
нашего магазина
Доставка по всей РФ
Точки самовывоза в Москве, курьерская доставка, отправка транспортными компаниями.
Лучшие цены
Мы являемся официальными дистрибьюторами и дилерами ведущих мировых брендов.
20+ лет на рынке
Мы работаем с 1998 года и поставляем только качественное оборудование.