DILH2200/22(RAW250)Контактор 2200А, управляющее напряжение 230-350В (АС, DC), категория применения AC-1
Основные характеристики
| Product range | Contactors |
| Application | Mains contactors for resistive loads from 1000 A |
| Subrange | AC -1 contactors greater than 1000 A |
| Utilization category | AC-1: Non-inductive or slightly inductive loads, resistance furnaces |
| Connection technique | Screw connection |
| Rated operational current | |
| AC-1Conventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith =Ie] | 2700 A |
| AC-1Conventional free air thermal current, 1 poleopen [Ith ] | 5500 A |
| Contact sequence | |
| For use with | DILM820-XHI… |
| Actuating voltage | RAW 250: 230 - 250 V 50 - 60 Hz/230 - 350 V DC |
| Voltage AC/DC | AC and DC operation |
| Auxiliary contacts | |
| possible variants at auxiliary contact module fitting options | on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA |
| Side mounting auxiliary contacts | |
| Instructions | Interlocked opposing contacts according to IEC/EN 60947-5-1 Appendix L, inside the auxiliary contact moduleAuxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open) |
| Instructions | integrated suppressor circuit in actuating electronics660 V, 690 V or 1000 V: not directly reversing |
| Note concerning the product | Classic DILM1600, DILH2000, DILH2200 A1/A2 werden wie bisher gewohnt an Spannung gelegt Direct from the PLC An die Anschlüsse A3/A4 kann direkt ein 24-V-Ausgang der SPS angeschlossen werden. From a low-power actuating device Gering belastbare Befehlsgeber wie Leiterplattenrelais, Befehlsgeräte oder Positionsschalter können direkt an A10/A11 angeschlossen werden. ① Stopping in the event of an emergency (emergency switching off)② max. Cable capacitance 6 nF |
| General | |
| Standards | IEC/EN 60947, VDE 0660, UL, CSA, CCC |
| Lifespan, mechanicalAC operated [Operations] | 5 x 106 |
| Lifespan, mechanicalDC operated [Operations] | 5 x 106 |
| Operating frequency, mechanicalAC operated [Operations/h] | 1000 |
| Operating frequency, mechanicalDC operated [Operations/h] | 1000 |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78Damp heat, cyclic, to IEC 60068-2-30 |
| Ambient temperatureOpen | -40 - +60 °C |
| Ambient temperatureStorage | - 40 - + 80 °C |
| Mounting position | |
| Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msMain contactsN/O contact | 10 g |
| Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msAuxiliary contactsN/O contact | 10 g |
| Mechanical shock resistance (IEC/EN 60068-2-27)Half-sinusoidal shock, 10 msAuxiliary contactsN/C contact | 8 g |
| Degree of Protection | IP00 |
| Weight | 32 kg |
| Terminal capacity main cableBusbar [Width] | 100 мм |
| Main cable connection screw/bolt | M12 |
| Tightening torque | 35 Nm |
| Terminal capacity control circuit cablesSolid | 1 x (0.75 - 2.5)2 x (0.75 - 2.5) mm2 |
| Terminal capacity control circuit cablesFlexible with ferrule | 1 x (0.75 - 2.5)2 x (0.75 - 2.5) mm2 |
| Terminal capacity control circuit cablesSolid or stranded | 18 - 14 AWG |
| Stripping length | 10 мм |
| Control circuit cable connection screw/bolt | M3.5 |
| Tightening torque | 1.2 Nm |
| ToolMain cableWidth across flats | 18 мм |
| ToolControl circuit cablesPozidriv screwdriver | 2 Size |
| ToolControl circuit cablesStandard screwdriver | 0.8 x 5.5/1 x 6 mm |
| Main conducting paths | |
| Rated impulse withstand voltage [Uimp] | 8000 V AC |
| Overvoltage category/pollution degree | III/3 |
| Rated insulation voltage [Ui] | 1000 V AC |
| Rated operational voltage [Ue] | 1000 V AC |
| Safe isolation to EN 61140between coil and contacts | 500 V AC |
| Safe isolation to EN 61140between the contacts | 500 V AC |
| Making capacity (p.f. to IEC/EN 60947) | 9840 A |
| Breaking capacity 220 V 230 V | 8200 A |
| Breaking capacity 380 V 400 V | 8200 A |
| Breaking capacity 500 V | 8200 A |
| Breaking capacity 660 V 690 V | 8200 A |
| Breaking capacity 1000 V | 5800 A |
| Component lifespan | AC1: See → Engineering, characteristic curves |
| AC | |
| AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 40 °C [Ith =Ie] | 2700 A |
| AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 50 °C [Ith =Ie] | 2400 A |
| AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 55 °C [Ith =Ie] | 2300 A |
| AC-1Rated operational currentConventional free air thermal current, 3 pole, 50 - 60 HzOpenat 60 °C [Ith =Ie] | 2200 A |
| AC-1Rated operational currentConventional free air thermal current, 1 poleNote | at maximum permissible ambient air temperature |
| AC-1Rated operational currentConventional free air thermal current, 1 poleopen [Ith ] | 5500 A |
| Current heat loss | |
| 3 pole, at Ith (60°) | 231 W |
| Magnet systems | |
| Voltage toleranceUS | 230 - 250 V 50/60 Hz230 - 350 V DC |
| Voltage toleranceAC operated [Pick-up] | 0.7 x US min - 1.15 x US max x US |
| Voltage toleranceDC operated [Pick-up] | 0.7 x US min - 1.15 x US max x US |
| Voltage toleranceAC operated [Drop-out] | 0.2 x US max - 0.6 x US min x US |
| Voltage toleranceDC operated [Drop-out] | 0.2 x US max - 0.6 x US min x US |
| Power consumption of the coil in a cold state and 1.0 x USNote on power consumption | Control transformer with uk ≦ 7% |
| Power consumption of the coil in a cold state and 1.0 x USPull-in power [Pick-up] | 1600 VA |
| Power consumption of the coil in a cold state and 1.0 x USPull-in power [Pick-up] | 1400 W |
| Power consumption of the coil in a cold state and 1.0 x USSealing power [Sealing] | 36.5 VA |
| Power consumption of the coil in a cold state and 1.0 x USSealing power [Sealing] | 17.3 W |
| Duty factor | 100 % DF |
| Changeover time at 100 % US (recommended value)Main contactsClosing delay | 70 ms |
| Changeover time at 100 % US (recommended value)Main contactsOpening delay | 40 ms |
| Behaviour in marginal and transitional conditionsSealingVoltage interruptions(0 … 0.2 x Uc min) ≦ 10 ms | Time is bridged successfully |
| Behaviour in marginal and transitional conditionsSealingVoltage interruptions(0 … 0.2 x Uc min) > 10 ms | Drop-out of the contactor |
| Behaviour in marginal and transitional conditionsSealingVoltage drops(0.2 … 0.6 x Uc min) ≦ 12 ms | Time is bridged successfully |
| Behaviour in marginal and transitional conditionsSealingVoltage drops(0.2 … 0.6 x Uc min) > 12 ms | Drop-out of the contactor |
| Behaviour in marginal and transitional conditionsSealingVoltage drops(0.6 … 0.7 x Uc min) | Contactor remains switched on |
| Behaviour in marginal and transitional conditionsSealingExcess voltage(1.15 … 1.3 x Uc max) | Contactor remains switched on |
| Behaviour in marginal and transitional conditionsSealingPick-up phase(0 … 0.7 x Uc min) | Contactor does not switch on |
| Behaviour in marginal and transitional conditionsSealingPick-up phase(0.7 x Uc min … 1.15 x Uc max) | Contactor switches on with certainty |
| Admissible transitional contact resistance (of the external control circuit device when actuating A11) | ≦ 500 mΩ |
| PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2)High | 15 V |
| PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2)Low | 5 V |
| Electromagnetic compatibility (EMC) | |
| Electromagnetic compatibility | This product is designed for operation in industrial environments (environment A). Its use in residential environments (environment B) may cause radio-frequency interference, requiring additional noise suppression measures. |
| Rating data for approved types | |
| Switching capacityGeneral use | 2200 A |
| Auxiliary contactsPilot DutyAC operated | A600 |
| Auxiliary contactsPilot DutyDC operated | P300 |
| Auxiliary contactsGeneral UseAC | 600 V |
| Auxiliary contactsGeneral UseAC | 15 A |
| Auxiliary contactsGeneral UseDC | 250 V |
| Auxiliary contactsGeneral UseDC | 1 A |
| Special Purpose RatingsResistance Air Heating480V 60Hz 3phase, 277V 60Hz 1phase | 2200 A |
| Special Purpose RatingsResistance Air Heating600V 60Hz 3phase, 347V 60Hz 1phase | 2200 A |
| Technical data for design verification | |
| Rated operational current for specified heat dissipation [In] | 2200 A |
| Heat dissipation per pole, current-dependent [Pvid] | 77 W |
| Equipment heat dissipation, current-dependent [Pvid] | 0 W |
| Static heat dissipation, non-current-dependent [Pvs] | 13 W |
| Heat dissipation capacity [Pdiss] | 0 W |
| Operating ambient temperature min. | -40 °C |
| Operating ambient temperature max. | +60 °C |
| IEC/EN 61439 design verification | |
| 10.2 Strength of materials and parts10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2 Strength of materials and parts10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2 Strength of materials and parts10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9 Insulation properties10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9 Insulation properties10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Low-voltage industrial components (EG000017) / Power contactor, AC switching (EC000066) | |
| Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching (ecl@ss10.0.1-27-37-10-03 [AAB718015]) | |
| Rated control supply voltage Us at AC 50HZ | 230 - 250 V |
| Rated control supply voltage Us at AC 60HZ | 230 - 250 V |
| Rated control supply voltage Us at DC | 230 - 250 V |
| Voltage type for actuating | AC/DC |
| Rated operation current Ie at AC-1, 400 V | 2700 A |
| Rated operation current Ie at AC-3, 400 V | 0 A |
| Rated operation power at AC-3, 400 V | 0 kW |
| Rated operation current Ie at AC-4, 400 V | 0 A |
| Rated operation power at AC-4, 400 V | 0 kW |
| Rated operation power NEMA | 0 kW |
| Modular version | No |
| Number of auxiliary contacts as normally open contact | 2 |
| Number of auxiliary contacts as normally closed contact | 2 |
| Type of electrical connection of main circuit | Rail connection |
| Number of normally closed contacts as main contact | |
| Number of main contacts as normally open contact | 3 |
| Product Standards | IEC/EN 60947-4-1; UL 60947-4-1; CSA - C22.2 No. 60947-4-1-14; CE marking |
| UL File No. | E29096 |
| UL Category Control No. | NLDX |
| CSA File No. | 012528 |
| CSA Class No. | 3211-04 |
| North America Certification | UL listed, CSA certified |
| Specially designed for North America | No |
| Side mounting auxiliary contacts | |
| possible variants at auxiliary contact module fitting options | on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA |
| Characteristic curve | |
| Switching conditions for 3 pole, non-motor loadsOperating characteristicsNon inductive and slightly inductive loadsElectrical characteristicsSwitch on: 1 x rated operational currentSwitch off: 1 x rated operational currentUtilization category100 % AC-1Typical examples of applicationElectric heat | |
| Characteristic curve | |
| Short-time loading, 3-poleTime interval between two loading cycles: 15 minutes |
| DILM1600DILH2000, DILH2200 |
На этой странице вы можете приобрести Eaton Контактор 2200А, управляющее напряжение 230-350В (АС, DC), категория применения AC-1 (артикул: 0000111793). Мы рекомендуем внимательно изучить представленные технические характеристики и ознакомиться с официальными брошюрами от Eaton, чтобы выбрать товар в нужной конфигурации.
Для покупки модели DILH2200/22(RAW250) просто нажмите кнопку «В корзину» и перейдите в корзину для оформления заказа. Большинство наших товаров имеются в наличии на складе; в случае отсутствия необходимой позиции мы обеспечим её поставку под заказ.
После оформления заказа наши менеджеры оперативно свяжутся с вами для уточнения деталей оплаты и наиболее удобных вариантов доставки.
Преимущества
нашего магазина
Доставка по всей РФ
Точки самовывоза в Москве, курьерская доставка, отправка транспортными компаниями.
Лучшие цены
Мы являемся официальными дистрибьюторами и дилерами ведущих мировых брендов.
20+ лет на рынке
Мы работаем с 1998 года и поставляем только качественное оборудование.