Основные характеристики
| IEC/EN 61439 design verification | |
| 10.2 Strength of materials and parts10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2 Strength of materials and parts10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2 Strength of materials and parts10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2 Strength of materials and parts10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9 Insulation properties10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9 Insulation properties10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Low-voltage industrial components (EG000017) / Phase separation plate for power circuit breaker (EC002035) | |
| Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV | |
| Model | Other |
На этой странице вы можете приобрести Eaton Межфазная перегородка BZM3 (артикул: 0000158300). Мы рекомендуем внимательно изучить представленные технические характеристики и ознакомиться с официальными брошюрами от Eaton, чтобы выбрать товар в нужной конфигурации.
Для покупки модели BZM3-XKP просто нажмите кнопку «В корзину» и перейдите в корзину для оформления заказа. Большинство наших товаров имеются в наличии на складе; в случае отсутствия необходимой позиции мы обеспечим её поставку под заказ.
После оформления заказа наши менеджеры оперативно свяжутся с вами для уточнения деталей оплаты и наиболее удобных вариантов доставки.
Преимущества
нашего магазина
Доставка по всей РФ
Точки самовывоза в Москве, курьерская доставка, отправка транспортными компаниями.
Лучшие цены
Мы являемся официальными дистрибьюторами и дилерами ведущих мировых брендов.
20+ лет на рынке
Мы работаем с 1998 года и поставляем только качественное оборудование.